General ParametersLife Expectancy The life expectancy of a Reed Relay is at least 105...106 operations at nominal load. At minimum load the life expectancy can be up to 5 x 108 operations. The mechanical life expectancy is 109 operations (minimum). Through the switching of higher loads, especially inductive or capacitive and lamp loads, life expectancy can be considerably reduced due to exceeding the permissible maximum current. Vibration and Shock Resistance During the evaluation of vibration and shock resistance, the relays are driven with nominal voltage. The switches should not open longer than 10 μsec. |
||||
|
||||
Washability Resistant to Caltron, Freon, alcohol and distilled (pure) water. During the final rinsing phase only the purest substances should be used. Capacitance The capacitance parameters are regarded as typical and are calculated for versions without shielding: |
||||
|
||||
Solderability |
||||
Switching Time When using dry Reed Switches in relays, contact bounce may occur. |
||||
|
||||
Comment |
||||
![]() |
||||
![]() |
||||
![]() |