DIL- SIL Reed Relays

The customer specific Reed Relays are Dual-In-Line-Relays with standard housing height of 7.5 mm and a base area of 19 x 10 mm. These relays are potted with a permanent flexible plastic material subject to no mechanical force.

The advantage of the customer specific DIL-Reed Relays is that a wide variation of special pin configurations, contact arrangements and other applications can be realized. S.T.G. is thus able to produce the relay to meet special customer requirements.

Due to the small housing these relays can replace standard housing relays mounted on a PCB.

Pull-in and Drop-out Voltage, Coil Resistance

The tolerances indicated are valid at 25 °C ± 3 °C. The temperaturen coefficient of the coil resistance is 0,4 % / °C.

Switching Voltage, Current and Capacity

The parameters as listed for switching voltage, current and capacity are maximum values.Exceeding any one of these values causes
overload and reduces relay life expectancy.

Contact Resistance

The contact resistance indicated is valid for new relays at nominal coil voltage. The four-point method at 2 VDC / 100 mA or 10 mA is applied.

Custom solutions for special applications, especially for switching signals smaller than 1 mV at 10 µA (low-level-applications) or applications requiring dynamic contact resistance measurement can be produced for special switching needs.

Temperature Range

The operating temperature of the relay is the equivalent of the internal temperature. If the relays are used in ambient temperatures higher than 20 °C, the maximum permissible operating voltage (UT) must be calculated according to the table indicated below, using the formula: UT = Umax x k1 (Umax = max. permissible operating voltage)


During and immediately after the soldering process no mechanical stress should occur on the soldering pins.

Customized special versions can be developed and manufactured pursuant to customer requirements.