Dielectric Strength
Tested
in a radiation (eg. light, X-ray) free environment by applying a DC voltage
across the open contacts, between adjacent contacts and between coil and
contact.
The test
current is 100 µA.
The
unused contacts should not be connected during the test.
Switching Time
Pull-in time including bounce time at nominal voltage and 20 Hz: 1,5 … 3,5
ms Release time (without diode) at nominal voltage and 20 Hz: 0,4 … 1,5 ms

Contact Capacitance:
|
Capacitance: |
N.O. |
|
Across open contacts |
0,8 - 1,2 pF |
|
Between open contacts and coil |
1,4 - 2,2 pF |
|
Between closed contacts and coil |
2,3 - 3,5 pF |
|