<< home

  >> Visit Stelvio S.P.A. webpage

  >> E. Bachem Gmbh & Co. KG    NEW !!! Download our catalogues ( 2008 )

Product Range

Reed Switches

Sensors

Proximity Switches

Security Sensors  -- NEW !!!

Dil-Sil Reed Relays

High Voltage Reed Relays

Solid State Relays

Inclination Switches Hg-free

Product Search

  Reed Switches

1 Normally Open Contact

1 Normally Closed Contact

1 N.O. and 1 N.C. Contacts

Bistable Contact

Advanced Search Wizard

  High Voltage Reed Relays  

1 Normally Open Contact

1 Normally Closed Contact

2 Normally Open Contacts

4 Normally Open Contacts

1 N.O. and 1 N.C. Contacts

Advanced Search Wizard

Quality System

Quality goals

ISO 9001:2000 Certificate

Our Partners

 Daimler Chrysler
 BOSCH Ansbach
BOSCH Rexroth
 Oki
 Kostal

 Stelvio S.P.A.

About us

Our team

Contact us

REEDSWITCHES

SENSORS

PROXIMITY SWITCHES

SECURITY SENSORS

HIGH VOLTAGE REED RELAYS

SOLID STATE RELAYS

INCLINATION SWITCHES

 

 << back to first page

 

Customer Specific

DIL-Reed Relays

 

- General Informations

- Standard Types

- Order Informations, Dimensions

 

General Informations

 

The customer specific Reed Relays are Dual-In-Line-Relays with standard housing height of 7,5 mm and a base area of 19 x 10 mm.These relays are potted with a permanent flexible plastic material subject to no mechanical force.

The advantage of the customer specific DIL-Reed Relays is that a wide variation of special pin configurations, contact arrangements and other applications can be realized. S.T.G. is thus able to produce the relay to meet special customer requirements.

Due to the small housing these relays can replace standard housing relays mounted on a PCB.

 

 

 

Pull-in and Drop-out Voltage, Coil Resistance

 

     The tolerances indicated are valid at 25 °C ± 3 °C. The temperaturen coefficient of the coil resistance is 0,4 % / °C.

 

Switching Voltage, Current and Capacity

 

     The parameters as listed for switching voltage, current and capacity are maximum values. Exceeding any one of these values causes overload and reduces relay life expectancy.

 

 

Contact Resistance

      The contact resistance indicated is valid for new relays at nominal coil voltage. The four-point method at 2 VDC / 100 mA or 10 mA is applied.

Custom solutions for special applications, especially for switching signals smaller than 1 mV at 10 µA (low-level-applications) or applications requiring dynamic contact resistance measurement can be produced for special switching needs.

 

>> Temperature Range

     The operating temperature of the relay is the equivalent of the internal temperature. If the relays are used in ambient temperatures higher than 20 °C, the maximum permissible operating voltage (UT) must be calculated according to the table indicated below, using the formula: UT = Umax x k1 (Umax = max. permissible operating voltage)

 

 

During and immediately after the soldering process no mechanical stress should occur on the soldering pins.

 

Customized special versions can be developed and manufactured pursuant to customer requirements.